The mainframe contains the controller and MIDI interface and a pair of coax. and optical inputs and outputs on the front panel, which double devices 31 and 32.
Eight modules can be inserted (each with 4 inputs and 4 outputs) to build a matrix from 6 x 6, upto 32 x 32. Any combination of modules may be assembled, so that AES, SP-DIF, and ADAT format can share one matrix. Any physical conversion between optical, coaxial, balanced and unbalanced is done within the matrix. If data conversion (CONSUMER/PROFESSIONAL) is needed please refer to our MQ4 format converter module.
ADAT format can be switched and distributed with the MOP4 module. If conversion between AES SP-DIF and ADAT "lightpipe" or TDIF1 is needed please refer to our MQA or MQT module.
MATRIX 32 x 32 crosspoint matrix 1 into 32 signal distribution
INPUTS, OUTPUTS depending on installed modules
PRESETS 50 memory locations
REMOTE MIDI program changes MIDI sysex. remote software